THE BAUER B-TROX SYSTEM


...
LOW PRESSURE MODULE
...
PURIFICATION MODULE
...
OX MODULE
...
HIGH PRESSURE MODULE


...
SAFE FILLING MODULE (Option)

Nitrox with TÜV certified safety

With B-TROX, BAUER is the only manufacturer worldwide offering a complete nitrox system certified ex works by TÜV (German Technical Inspection Authority).All components are perfectly matched for providing a maximum of safety. Manufactured for reliable Nitrox supply of stationary professional diving centres, safari boats, liveabroads, yachts and cruise liners as well as for commercial missions.

Nitrox – Advantages and Risks

Longer zero hours for diving

Shorter decompression times due to the reduced nitrogen content in the breathing air

Reduction of the necessary time at surface

Less stress when rising and diving frequently

Components of the BAUER B-TROX System:

  1. LOW PRESSURE MODULE – The LOW PRESSURE MODULE compresses the ambient air taken in to about 10 bar, so that the OX MODULE is supplied with the required air quantity / pressure for separating off the nitrogen. The screw compressor used for this is produced in-house by BAUER.
  2. PURIFICATION MODULE – The ETC converter in the PURIFICATION MODULE removes the oil contained in the pre-compressed air totally, using the catalytic process. This is necessary as otherwise the oxygen membrane in the OX MODULE would be damaged permanently by polluted air.
  3. OX MODULE – The oxygen membrane of the OX MODULE separates the required quantity of nitrogen from the breathing air until the predefined proportion of oxygen of the selected nitrox mixture is achieved.
  4. HIGH PRESSURE MODULE – The nitrox mixture generated from the OX MODULE is reliably compressed in the HIGH PRESSURE MODULE to a filling pressure of 200 bar.
  5. SAFE FILLING MODULE (Option) – The steel chamber of the SAFE FILLING MODULE B-SAFE 300 offers attendant persons increased protection during the filling process.

Technical Data

Plant network B-TROX system
Medium Nitrox (air) 36% or 40%
Intake pressure Atmospheric
Maximum operating pressure (HD) 225 bar (at the safety valve)
Permissible ambient temperature +5 to +40 °C
Permissible altitude 0 to 1500 m above sea level
Operating voltage 400/230 V

Technical Data

Model Number of comp. stages F.A.D. R.P.M. Fillling rate Drive Purification system Dimensions approx. cm Weight net approx.
max. 200 bar   l/min 1) min-1 min 2) kW HP P-Range L W H kg
KAP 12.14 – OX-5,5-5 4 260 1185 0,8 5,5 7,5 P61 114 83 152 305
KAP 12.14 – OX-7,5-5 4 320 1450 0,6 7,5 10 P61 114 83 152 310
KAP 12.14 – OX-11-5 4 450 1320 0,4 11 15 P61 114 83 152 350
V 12.14 – OX-5,5-5 4 260 1185 0,8 5,5 7,5 P61 148 83 152 395
V 12.14 – OX-7,5-5 4 320 1450 0,6 7,5 10 P61 148 83 152 400
V 15.1 – OX-11-5 4 450 1320 0,4 11 15 p61 148 83 152 440

1) Cylinder filling from 0 to 200 bar

2) Filling rate for 1 l cylinder capacity from 0 to 200 bar

Scope of Supply

Basic module

Equipment high-pressure compressor:

  • 3 and/or 4-stage blocks
  • Oxygen content: 36% or 40%
  • Delivery rate: 260, 320 or 450 l/min
  • Electric motor:  5.5 - 11 kW
  • Control system: B-CONTROL II
  • Filter system: P61, breathing air quality as per DIN EN 12021
  • Automatic condensate drain
  • Final pressure safety valve
  • Pressure maintaining valve
  • Super Silent housing
Optionen
  • Filling device PN200 Nitrox as per DIN EN 144-3
  • SECURUS filter cartridge monitoring system for the efficient use of filter cartridges
  • PureAir certification possible
  • Filter system P81 for longer filter cartridge lives
  • B-SAFE 300-OX for maximum safety of persons and filling rooms

2021 Halchem Lanka Pvt Ltd All rights reserved

Touch with us

No. 81, Welikada Watte Road, Rajagiriya,Sri Jayawardhanepura.
Hot-Line : +94 112514495/6
Fax: +94 112514492
E-mail: [email protected]

Member of


We Are Bit Social
Hosted By