GIB-BOOSTER-SERIES, HIGH PRESSURE, WATER COOLED, 90–420 BAR (NITROGEN)


High Pressure Gas Compressors for Inert Gases (Nitrogen), GIB-Booster Series, High Pressure, water cooled

Vertical version: GIB 23 Booster Range 90–420 bar, water cooled

Model Free air delivery * Number of stages Intake pressure Final pressure
min – max
Speed Motor power Power consumption GIB 23
l/min m³/h cfm bar g bar bar rpm kW kW
Technical Data GIB 23 Booster Range, vertical version, water cooled
Booster Range GIB, 90 to 350 bar
GIB 23.10-37 1330 80 47 4 2 90 200 1140 37 19
1775 106 63 3 150 300 26
2218 133 78 4 200 350 32
2440 146 86 4,5 200 350 35
GIB 23.12-37 1545 92 55 4 4,5 90 200 1140 37 19
1965 117 69 6 150 300 25
2527 151 89 8 200 350 31
3090 185 109 10 200 350 35
GIB 23.13-37 1970 118 70 4 8 150 200 1140 37 20
2410 144 85 10 150 300 26
2850 170 101 12 200 350 31
3287 197 116 14 200 350 34
GIB 23.14-37 1850 111 65 3 16 150 250 1140 37 18
2280 137 81 20 150 300 22
3600 202 119 30 200 350 31
4500 254 150 38 200 350 35
Booster Range GIB 23, 200 to 420 bar
GIB 23.5-37 2400 145 85 4 10 200 420 1140 37 30
2850 170 101 12 200 420 33

Horizontal version: GIB 24 Booster Range 90–350 bar, water cooled

Model Free air delivery * Number of stages Intake pressure Final pressure
min – max
Speed Motor power Power consumption GIB 24
l/min m³/h cfm bar g bar bar rpm kW kW
Technical Data GIB 24 Booster Range, horizontal version
GIB 24.11-75 2200 132 77 4 1 90 200 1485 75 35
3200 192 113 2 150 300 51
4200 252 148 3 150 350 64
5240 314 185 4,5 200 350 74
GIB 24.12-75 2500 150 88 4 4 120 300 1485 75 35
3500 210 123 6 150 350 46
4500 270 159 8 200 350 55
5500 330 196 10 220 350 63
GIB 24.13-55 2480 149 87 4 8 150 350 1485 55 31
3300 198 117 11 150 350 37
4140 248 146 14 200 350 43
4700 282 166 16 250 350 47

Horizontal version: GIB 26 Booster Range 90–350 bar, water cooled

Model Free air delivery * Number of stages Intake pressure Final pressure
min – max
Speed Motor power Power consumption GIB 26
l/min m³/h cfm bar g bar bar rpm kW kW
Technical Data GIB 26 Booster Range, horizontal version, water cooled
Compressor Range, 90 to 350 bar
I 26.2-45 1790 107 63 4 atm. 90 350 985 45 38
I 26.2-55 2700 162 95 atm. 90 350 1485 75 58
GIB 26.2-110 5400 324 190 1 150 350 1485 110 98
Booster Range GIB, 90 to 350 bar
GIB 26.10-132 4900 294 173 4 2 90 200 1485 132 71
6700 402 237 3 150 350 103
8500 510 300 4 200 350 123
9400 564 332 4,5 200 350 131
GIB 26.12-132 5100 306 180 4 4,5 90 250 1485 132 66
6500 390 230 6 150 350 86
8300 498 293 8 200 350 102
10200 612 360 10 200 350 116
GIB 26.13-132 7600 456 268 4 10 150 350 1485 132 87
9000 540 318 12 150 350 98
10350 621 365 14 200 350 107
12400 744 438 17 250 350 119
GIB 26.14-132 5100 306 180 3 17 150 250 1485 110 47
6000 360 212 20 150 350 59
9300 558 328 30 200 350 78
11700 702 413 38 250 350 88

* Conveying volume flow rate acc. to ISO 1217

Diagram of a Ready-to-run Compressor System

Compression Treatment Storage Distribution

2021 Halchem Lanka Pvt Ltd All rights reserved

Touch with us

No. 81, Welikada Watte Road, Rajagiriya,Sri Jayawardhanepura.
Hot-Line : +94 112514495/6
Fax: +94 112514492
E-mail: [email protected]